Insulation R-value calculator

Pick your climate zone, what is already in the attic and how deep it is, and the insulation you plan to add. RValueCalc estimates the R-value you have, how much more you need to reach the target and how many inches of the new material that takes, using typical R-values per inch from the US Department of Energy. The example is an attic in zone 5 with 4 inches of old loose-fill fiberglass (about R-10), topped up to R-60 with blown cellulose: about 14 more inches.

US R-values (ft²·°F·h/BTU), inches

    Saved you some time? Leave a tip, entirely optional.

    It also converts R to U-factor and metric RSI and shows how much heat flow through the insulation drops.

    How the R-value calculator works

    RValueCalc multiplies the depth of the existing insulation by its typical R-value per inch, subtracts that from your target and divides the rest by the new material's R-value per inch. The range uses the lowest and highest per-inch values in the chart. U = 1 ÷ R, RSI = R × 0.1761 and heat flow = area × temperature difference ÷ R.

    R-value per inch

    MaterialR per inchTypicalInches for R-30Inches for R-49
    Fiberglass batt2.9–3.83.29.415.3
    Loose-fill fiberglass2.2–2.72.51219.6
    Loose-fill cellulose3.2–3.83.58.614
    Mineral wool batt3–4.347.512.3
    Loose-fill mineral wool2.8–3.331016.3
    Open-cell spray foam3.5–3.73.68.313.6
    Closed-cell spray foam6–76.54.67.5
    EPS foam board3.6–4.447.512.3
    XPS foam board4.6–5569.8
    Polyiso foam board5.6–6.5658.2

    ENERGY STAR recommended R-values (existing wood-framed homes)

    ZoneAttic, uninsulatedAttic with 3–4″ alreadyFloor
    Zone 1R-30add R-25R-13
    Zone 2R-49add R-38R-13
    Zone 3R-49add R-38R-19
    Zones 4A and 4BR-60add R-49R-19
    Zones 4C, 5 and 6R-60add R-49R-30
    Zones 7 and 8R-60add R-49R-38

    Per-inch values: US Department of Energy and Building America Solution Center (PNNL) typical ranges; mineral wool batts vary most (older batts ≈ R-3.1, current stone-wool batts up to ≈ R-4.3). Recommended levels: ENERGY STAR, based on 2021 IECC Table R402.1.3. Results are estimates: product labels give the rated R-value for a stated thickness, and local codes set the legal minimums.

    Frequently asked questions

    What R-value should my attic be?

    ENERGY STAR recommends R-30 in zone 1, R-49 in zones 2–3 and R-60 in zones 4–8 for an uninsulated attic.

    How many inches is R-60?

    About 17 inches of blown cellulose (R-3.5 per inch) or 24 inches of loose-fill fiberglass (R-2.5 per inch).

    Are the results exact?

    No. R-value per inch varies by product, density and settling. Bag and batt labels give the installed R-value for a given depth; use them for the final order.

    Is RValueCalc free?

    Yes, with no sign-up or ads.

    Are my inputs saved?

    Yes, in this browser only.