Insulation R-value chart

The chart below lists typical R-values per inch for common insulation materials, with the range you will see across products and the thickness needed for R-30 and R-49. Loose-fill fiberglass has the lowest R per inch of the common materials and closed-cell foam the highest. RValueCalc uses the typical figures in the calculator; pick a material and target above to see your own numbers.

US R-values (ft²·°F·h/BTU), inches

    Saved you some time? Leave a tip, entirely optional.

    Values are from the US Department of Energy and the Building America Solution Center. Polyiso boards lose some R-value in very cold weather.

    How the R-value calculator works

    RValueCalc multiplies the depth of the existing insulation by its typical R-value per inch, subtracts that from your target and divides the rest by the new material's R-value per inch. The range uses the lowest and highest per-inch values in the chart. U = 1 ÷ R, RSI = R × 0.1761 and heat flow = area × temperature difference ÷ R.

    R-value per inch

    MaterialR per inchTypicalInches for R-30Inches for R-49
    Fiberglass batt2.9–3.83.29.415.3
    Loose-fill fiberglass2.2–2.72.51219.6
    Loose-fill cellulose3.2–3.83.58.614
    Mineral wool batt3–4.347.512.3
    Loose-fill mineral wool2.8–3.331016.3
    Open-cell spray foam3.5–3.73.68.313.6
    Closed-cell spray foam6–76.54.67.5
    EPS foam board3.6–4.447.512.3
    XPS foam board4.6–5569.8
    Polyiso foam board5.6–6.5658.2

    ENERGY STAR recommended R-values (existing wood-framed homes)

    ZoneAttic, uninsulatedAttic with 3–4″ alreadyFloor
    Zone 1R-30add R-25R-13
    Zone 2R-49add R-38R-13
    Zone 3R-49add R-38R-19
    Zones 4A and 4BR-60add R-49R-19
    Zones 4C, 5 and 6R-60add R-49R-30
    Zones 7 and 8R-60add R-49R-38

    Per-inch values: US Department of Energy and Building America Solution Center (PNNL) typical ranges; mineral wool batts vary most (older batts ≈ R-3.1, current stone-wool batts up to ≈ R-4.3). Recommended levels: ENERGY STAR, based on 2021 IECC Table R402.1.3. Results are estimates: product labels give the rated R-value for a stated thickness, and local codes set the legal minimums.

    Frequently asked questions

    What is the R-value of fiberglass per inch?

    About R-2.9 to R-3.8 for batts and R-2.2 to R-2.7 for loose fill.

    What is the R-value of cellulose per inch?

    About R-3.2 to R-3.8 when settled.

    Is XPS or EPS better?

    XPS is about R-5 per inch and EPS about R-4, but EPS costs less per R and keeps its R-value well. Both work as rigid insulation.