Insulation heat loss calculator

Heat flows through insulation at a rate of area × temperature difference ÷ R-value, in BTU per hour. This page starts with 400 square feet of wall insulated with 3½ inches of fiberglass (about R-11) and adds R-10 of foam board outside for R-21, with a 50 °F difference between inside and outside. Heat flow through the insulation drops from about 1,790 to 950 BTU/h. RValueCalc also shows the figure in watts.

US R-values (ft²·°F·h/BTU), inches

    Saved you some time? Leave a tip, entirely optional.

    This is the flow through the insulation layer only. Studs, windows, air leaks and other layers change the whole-wall figure, so use it to compare options, not to size a furnace.

    How the R-value calculator works

    RValueCalc multiplies the depth of the existing insulation by its typical R-value per inch, subtracts that from your target and divides the rest by the new material's R-value per inch. The range uses the lowest and highest per-inch values in the chart. U = 1 ÷ R, RSI = R × 0.1761 and heat flow = area × temperature difference ÷ R.

    R-value per inch

    MaterialR per inchTypicalInches for R-30Inches for R-49
    Fiberglass batt2.9–3.83.29.415.3
    Loose-fill fiberglass2.2–2.72.51219.6
    Loose-fill cellulose3.2–3.83.58.614
    Mineral wool batt3–4.347.512.3
    Loose-fill mineral wool2.8–3.331016.3
    Open-cell spray foam3.5–3.73.68.313.6
    Closed-cell spray foam6–76.54.67.5
    EPS foam board3.6–4.447.512.3
    XPS foam board4.6–5569.8
    Polyiso foam board5.6–6.5658.2

    ENERGY STAR recommended R-values (existing wood-framed homes)

    ZoneAttic, uninsulatedAttic with 3–4″ alreadyFloor
    Zone 1R-30add R-25R-13
    Zone 2R-49add R-38R-13
    Zone 3R-49add R-38R-19
    Zones 4A and 4BR-60add R-49R-19
    Zones 4C, 5 and 6R-60add R-49R-30
    Zones 7 and 8R-60add R-49R-38

    Per-inch values: US Department of Energy and Building America Solution Center (PNNL) typical ranges; mineral wool batts vary most (older batts ≈ R-3.1, current stone-wool batts up to ≈ R-4.3). Recommended levels: ENERGY STAR, based on 2021 IECC Table R402.1.3. Results are estimates: product labels give the rated R-value for a stated thickness, and local codes set the legal minimums.

    Frequently asked questions

    How do I calculate heat loss through a wall?

    Q = A × ΔT ÷ R: area in square feet times the temperature difference in °F, divided by the R-value, gives BTU per hour.

    Does doubling R-value halve heat loss?

    Yes, through that layer. Going from R-30 to R-60 halves the loss again, but saves fewer BTUs than going from R-10 to R-30.

    How many watts is a BTU per hour?

    1 BTU/h = 0.293 W, so 1,000 BTU/h is about 293 W.

    Is RValueCalc free?

    Yes, with no sign-up or ads.

    Are my inputs saved?

    Yes, in this browser only.